CyberPower PDU15SW8RNET Uživatelský manuál Strana 72

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 100
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 71
PowerPanel™ Business Edition
71
z Address: The IP address of the UPS RMCARD, PDU or Agent computer’s network interface.
z PC & Equip: The number of the powered computers and equipment.
z Outlets: The amount of outlets on the UPS/PDU.
z Outlet On: The outlets which are supplying power.
z Outlet Off: The outlets which are not supplying power.
z Power Source: The power source of the UPS, e.g. Utility or Battery.
z Remaining Runtime: The estimated amount of time remaining that the UPS can supply power, given its
current load.
z Capacity: The capacity of the batteries expressed as a percentage of full charge.
z Statistics: Indicates the state of the device as Normal, Severe, Warning or Untouched.
Severe: Devices with severe-level events such as Overheat or Output is off.
Warning: Devices with warning-level events such as Utility power failure or Battery need
replacement.
Untouched: Devices which have lost communication with Center.
z Type: The type of software the selected device is running, e.g. Agent, Client or Equipment.
Status
The Status tab displays details about the UPS/PDU.
z Current: The output current in Amps.
z Outlets: The status of each outlet on the UPS/PDU and the name of the connected computer or
equipment.
z Input: Displays the status of the utility power supplied to the UPS.
z Voltage: The voltage of the utility power supplied to the UPS.
z Frequency: The frequency of the utility power supplied to the UPS in Hertz.
z Output: Displays the status of the output power that is being supplied to connected equipment.
z Load Consumption: The power draw of the connected equipment expressed as a percentage of the
total load capacity. This displays as watts on some UPS models.
z Battery: Displays the status of the battery packs.
z Capacity: The capacity of the batteries, expressed as a percentage of full charge.
z Remaining Runtime: The estimated amount of time that the UPS can supply power to its load.
z System: Displays the operating status of the UPS.
Information
Information tab shows information about the PDU or UPS.
z Model Name: The model name of the UPS/PDU.
z Firmware Version: The firmware version of the UPS/PDU.
z MAC address: The MAC address of the UPS RMCARD, PDU or Agent computer's network interface.
z Serial Number: The serial number of the UPS. Note: This will give the internal serial number on some
models.
Zobrazit stránku 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 99 100

Komentáře k této Příručce

Žádné komentáře